Quantum heat pumps at a glance

Models on our list
Compact 150, 200, 270 and 340, Titan Compact 340
Booster element
None, per Quantum
Works down to
Minus 10 degrees outside, per Quantum
Refrigerant on listed models
R134a

Quantum heat pump hot water in Adelaide

Quantum heat pumps, which we supply and install, plus repairs on Quantum units already running in Adelaide homes.

Local business since 1985 Same day for most customers.

All makes and models, including

BoschRheemRinnaiDuxVulcan

AlsoAquaMAXApricusMideaReclaim EnergySanden

Quantum heat pumps

A Quantum heat pump takes heat out of the outside air and moves it into the water in the tank. Quantum says its units do this without an electric booster element, in outside temperatures down to minus 10 degrees.

Quantum is one of the heat pump brands we fit, along with Rheem, Reclaim Energy, Sanden, Apricus and Midea. The models on this page come from our earlier Quantum list, so ring us for the sizes available now. Heat pump hot water compares the brands side by side.

Quantum jobs

  • New Quantum installsSupplied and fitted, with the old tank taken away.
  • Electric tank to QuantumA heat pump in place of an electric tank.
  • Stopped heatingOlder Quantum units that run but don't heat, or show a fault.
  • SizingMatched to how many people live in the house.
Send us a photo of your Quantum

Quantum range

Models we supply and service

The main Quantum models in the current Australian range, with the details Quantum publishes. Not sure which suits your home? Ring us and we will talk it through.

  • Heat pump (all-in-one)

    Quantum 150L heat pump (150-08AC6-290)

    150 L tank, 130 L rated delivery

    • R290 refrigerant
    • No electric booster element (Quantum)
    • Operates from -10 to +40°C outside
    • Maximum tank setting 60°C
    • 10 amp circuit
    • COP 4.3 at 20°C
    • Sound level 50 dB

    Suits: 1 to 2 people, 1 bathroom (Quantum)

  • Heat pump (all-in-one)

    Quantum 200L heat pump (200-08AC6-290)

    200 L tank, 175 L rated delivery

    • R290 refrigerant
    • No electric booster element (Quantum)
    • Operates from -10 to +40°C outside
    • Maximum tank setting 60°C
    • 10 amp circuit
    • COP 4.3 at 20°C
    • Sound level 50 dB

    Suits: 3 people, 2 bathrooms (Quantum)

  • Heat pump (all-in-one)

    Quantum 270L heat pump (270-08AC6-290)

    270 L tank, 250 L rated delivery

    • R290 refrigerant
    • No electric booster element (Quantum)
    • Operates from -10 to +40°C outside
    • Maximum tank setting 60°C
    • 10 amp circuit
    • COP 4.53 at 20°C
    • Sound level 48 dB

    Suits: 3 to 5 people, 2 bathrooms (Quantum)

  • Heat pump (all-in-one)

    Quantum 340L heat pump (340-08AC6-290)

    340 L tank, 315 L rated delivery

    • R290 refrigerant
    • No electric booster element (Quantum)
    • Operates from -10 to +40°C outside
    • Maximum tank setting 60°C
    • 10 amp circuit
    • COP 4.53 at 20°C
    • Sound level 48 dB

    Suits: Up to 7 people, 3 bathrooms (Quantum)

Where a Quantum heat pump goes

A heat pump needs moving air, so it goes outside with some space around it. Like any heat pump it hums while it runs, a bit like an air conditioner's outdoor unit, so we keep it away from bedroom windows and the neighbour's fence where we can.

It also needs a drain for the condensation it makes and the right power circuit. We look at all three before we quote.

Quantum pages: Quantum brochures · Heat pump hot water

Rebates and running costs

Eligible heat pumps earn small-scale technology certificates (STCs) until that scheme ends in 2030, and they come off the price. The SA REPS incentive used up its 2026 allocation and is due to be renegotiated in early 2027, so check with us for where it stands.

Heat pumps are usually the cheapest hot water to run, and cheaper again if you have rooftop solar. The Household Energy Upgrades Fund also offers discounted loans through partner lenders.

Read more: Rebates · Heat pump vs gas vs electric

Quantum models and specificationsThe Compact and Titan Compact models from our earlier list, with sizes, ratings and specifications.

Quantum Heat Pump Systems

Compact 150L

Quantum Compact 150L Heat Pump Hot Water System

  • Small Households
  • 130 Litre (Rated Size)
  • 5 Year Cylinder Warranty
  • 1 Year Parts & Labour Warranty
  • Vitreous Enamel Cylinder
  • 10 Amps
  • External Installation

Compact 200L

Quantum Compact 200L Heat Pump Hot Water System

  • Small-Average Households
  • 175 Litre (Rated Size)
  • 5 Year Cylinder Warranty
  • 1 Year Parts & Labour Warranty
  • Vitreous Enamel Cylinder
  • 15 Amps
  • External Installation

Compact 270L

Quantum Compact 270L Heat Pump Hot Water System

  • Average Households
  • 250 Litre (Rated Size)
  • 5 Year Cylinder Warranty
  • 1 Year Parts & Labour Warranty
  • Vitreous Enamel Cylinder
  • 15 Amps
  • External Installation

Compact 340L

Quantum Compact 340L Heat Pump Hot Water System

  • Large Households
  • 315 Litre (Rated Size)
  • 5 Year Cylinder Warranty
  • 1 Year Parts & Labour Warranty
  • Vitreous Enamel Cylinder
  • 15 Amps
  • External Installation

Titan Comp. 340L

Quantum Titan Compact 340L Heat Pump System

  • Extra Large Households
  • 315 Litre (Rated Size)
  • 5 Year Cylinder Warranty
  • 1 Year Parts & Labour Warranty
  • Vitreous Enamel Cylinder
  • 15 Amps
  • External Installation

Quantum Heat Pump Hot Water Systems – Technical Specifications

Quantum Heat Pump

Quantum Heat Pump Systems from Adelaide Hot Water

Quantum heat pump technical specifications for the current systems include the Quantum Compact 150L heat pump hot water system, the Quantum Compact 200L heat pump system, the Quantum Compact 270L hot water system, the Quantum Compact 340L heat pump hot water system and the Quantum Titan Compact 340L heat pump hot water system. If you need more information about the Quantum heat pump hot water systems call Adelaide Hot Water TM today. Not sure which Quantum hot water heater is right for you? Call us today for specialist Adelaide heat pump advice on (08) 8444 7311.

Compact 150L

Quantum Compact 150L heat pump hot water from Adelaide Hot Water.

Specifications Model Compact 150L Model Number 150-08ACW-134 Rated Size (Litres) 130 Heating Output (kW) 2.45 Power input (kW) 0.66 COP of heating 3.67 Compressor 16.55cc* Rotary Refrigerant R134 Electrical supply 220-240V/50Hz/1Ph Ciruit 10 Amps Water connections 3 slash 4 PTR valve setting 1000kPa ECV setting 850kPa PLV without ECV fitted 500-600kPa PLV with ECV fitted 350-500kPa Operating sound level at 1.5M 50dBA Dimensions ( Height * Diameter ) 1620 mm x 540mm Nett (empty) weight 100 kg Ambient air operating temperature -10 °C to +40 °C Maximum temperature 70 °C Water temp setting 60 °C Hot water production rate L/hr (COP) 53 (3.67)

Compact 200L

Quantum Compact 200L heat pump hot water from Adelaide Hot Water.

Specifications Model Compact 200L Model Number 200-08ACW-134 Rated Size (Litres) 175 Heating Output (kW) 2.45 Power input (kW) 0.66 COP of heating 3.67 Compressor 16.55cc* Rotary Refrigerant R134a Electrical supply 220-240V/50Hz/1Ph Ciruit 15 Amps Water connections 3 slash 4 PTR valve setting 1,000kPa ECV setting 850kPa PLV without ECV fitted 500-600kPa PLV with ECV fitted 350-500kPa Operating sound level at 1.5M 48dB (A) (*45dB(A) Dimensions ( Height * Diameter ) 1900 mm x 650mm Nett (empty) weight 135 kg Ambient air operating temperature -10 °C to +40 °C Maximum temperature 70 °C Water temp setting 60 °C Hot water production rate L/hr (COP) 77 (3.88)

Compact 270L

Quantum Compact 270L heat pump hot water from Adelaide Hot Water.

Specifications Model Compact 270L Model Number 270-11AC4-134 Rated Size (Litres) 250 Heating Output (kW) 3.83 Power input (kW) 0.99 COP of heating 3.88 Compressor 23.1cc* Refrigerant R134a Electrical supply 220-240V/50Hz/1Ph Ciruit 15 Amps Water connections 3 slash 4 BSP – 20mm PTR valve setting 1,000kPa ECV setting 850kPa PLV without ECV fitted 500-600kPa PLV with ECV fitted 350-500kPa Operating sound level at 1.5M 48dB (A) (*45dB(A) Dimensions ( Height * Diameter ) 1900 mm x 650 mm Nett (empty) weight 135 kg Ambient air operating temperature -10 °C to +40 °C Maximum temperature 70 °C Water temp setting 60 °C Hot water production rate L/hr (COP) 77 (3.88)

Compact 340L

Quantum Compact 340L heat pump hot water from Adelaide Hot Water.

Specifications Model Compact 340L Model Number 340-11AC4-134 Rated Size (Litres) 315 Heating Output (kW) 3.83 Power input (kW) 0.99 COP of heating 3.88 Compressor 23.1cc* Refrigerant R134a Electrical supply 220-240V/50Hz/1Ph Ciruit 15 Amps Water connections 3 slash 4 BSP PTR valve setting 1,000kPa ECV setting 850kPa PLV without ECV fitted 500 or 600 kPa PLV with ECV fitted 350 or 500 kPa Operating sound level at 1.5M 48dB (A) (*45dB(A) Dimensions ( Height * Diameter ) 1900mm x 650mm Nett (empty) weight 135kg Ambient air operating temperature -10°C to +40°C Maximum temperature 70 °C Water temp setting 60 °C Hot water production rate L/hr (COP) 77 (3.88)

Titan Compact 340L

Quantum Titan Compact 340L heat pump hot water from Adelaide Hot Water.

Specifications Model Titan Compact 340L Model Number 340-17ACW-134 Rated Size (Litres) 315 Heating Output (kW) 6.22 Power input (kW) 1.66 COP of heating 3.74 Compressor 39 cc* Refrigerant R134a Electrical supply 220-240V/50Hz/1Ph Ciruit 15 Amps Water connections 3 slash 4 PTR valve setting 1,000kPa ECV setting 850kPa PLV without ECV fitted 500 or 600 kPa PLV with ECV fitted 350 or 500 kPa Operating sound level at 1.5M 58dBA Dimensions ( Height * Diameter ) 2300mm X 650mm Nett (empty) weight 180kg Ambient air operating temperature -10 °C to +40 °C Maximum temperature 70 °C Water temp setting 60 °C Hot water production rate L/hr (COP) 134 (3.74)

Heat Pump Hot Water

What happens when you call

  1. 1

    Call or send photos

    Ring (08) 8444 7311, or send photos below.

  2. 2

    We come out

    A local plumber.

  3. 3

    Price first

    Agreed before any work starts.

  4. 4

    Hot water back on

    Tested, and the old unit taken away.

Quantum heat pumps questions

Not answered here? Ring (08) 8444 7311 and ask.

Do Quantum heat pumps have a booster element?

Quantum says its heat pumps don't need one, and that they keep heating down to minus 10 degrees outside.

Do you repair older Quantum heat pumps?

Yes. Ring with the model number from the sticker plate, such as 270-11AC4-134, and tell us what the unit is doing.

Which Quantum size do I need?

It depends on how many people live in the house and how you use hot water. Our earlier list ran from the Compact 150 for small households to the Titan Compact 340 for big ones. Ring us for current sizes.

Request a Fast Quote – Quantum Heat Pump Hot Water in Adelaide

Call us on (08) 8444 7311

Or send the details and a photo of the unit. We'll call you back.

Photos or PDFs (optional, up to 6)

    A photo of the unit and its sticker plate helps us bring the right parts.

    Call nowGet a quote